An internal equipment failure of the specified nonvolatile memory (NVM) module, or a communications problem between the NVM module and the SYSCTL circuit pack was detected.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN) Default: Critical (CR) |
ASAP Type |
Non-Volatile Memory Module |
AID Type |
NVM |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
WKGMEM (Working Memory Failure) |
Effect on Service |
NSA |
Alarm Entity Type |
EQPT |
Description |
NVM failed |
Likely Cause |
The NVM module failed. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the circuit pack. The IND display shows N0x where x is the failed NVM number. |
Action |
Proceed to Procedure 5-106: Clear "NVM" alarms. |