inc. OCN RFI-L

Description

The system has detected a line remote failure indicator (RFI-L) on an incoming OC-N line, indicating that the far-end network element has detected an incoming signal failure. This alarm was previously called far-end-receive-failure (FERF) and remote defect indication line (RDI-L).

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Not Alarmed (NA)

ASAP Type

OCn Port

AID Type

OC-N Line

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

FERF [Line RDI-L (Far End Remote Failure)]

Effect on Service

NSA

Alarm Entity Type

OC3, OC12, OC48, or OC192

Description

inc. OC3 RFI-L,

inc. OC12 RFI-L,

inc. OC48 RFI-L, or

inc. OC192 RFI-L

Likely Cause

An incoming signal failure was detected at the far-end network element.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively)

Action

Proceed to Procedure 5-69: Clear "inc. OCN RFI-L" alarm.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.