inc. ODU2 BDI

Description

The system has detected a backward defect indicator (BDI) on an incoming 10G optical channel data unit (ODU2) signal (from the OTU2 port), indicating that the far-end network element has detected an incoming ODU2 signal failure.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Not Alarmed (NA)

ASAP Type

ODU2 Tributary

AID Type

ODU2 Tributary

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

BDI (Backward Defect Indication)

Effect on Service

NSA

Alarm Entity Type

ODU2

Description

inc. ODU2 BDI

Likely Cause

An incoming ODU2 signal failure was detected at the far-end network element.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively)

Action

Proceed to Procedure 5-11: Clear "inc. BDI" alarms.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.