unexpected or failed Pluggable Transmission Module

Description

An internal equipment failure of the specified pluggable transmission module was detected, the wrong pluggable transmission module was inserted into the socket, or a communications problem between the pluggable transmission module and the SYSCTL circuit pack was detected.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

SA Default: Critical (CR)

NSA Default: Minor (MN)

ASAP Type

Pluggable Transmission Module

AID Type

Socket

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

FACTERM (Facility termination equipment failure)

Effect on Service

SA or NSA

Alarm Entity Type

EQPT

Description

unexpected or failed Pluggable Transmission Module

Likely Cause

An unprotected pluggable transmission module failed or the wrong pluggable transmission module was inserted into an unprotected socket - SA.

A protected pluggable transmission module failed or the wrong pluggable transmission module was inserted into a protected socket - NSA.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively), a continuously lighted Fault LED on the failed pluggable transmission module socket, and a flashing Fault LED on the circuit pack.

Action

Proceed to Procedure 5-143: Clear "unexpected or failed Pluggable Transmission Module" alarm.