An internal equipment failure of the specified pluggable transmission module was detected, the wrong pluggable transmission module was inserted into the socket, or a communications problem between the pluggable transmission module and the SYSCTL circuit pack was detected.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) SA Default: Critical (CR) NSA Default: Minor (MN) |
ASAP Type |
Pluggable Transmission Module |
AID Type |
Socket |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
FACTERM (Facility termination equipment failure) |
Effect on Service |
SA or NSA |
Alarm Entity Type |
EQPT |
Description |
unexpected or failed Pluggable Transmission Module |
Likely Cause |
An unprotected pluggable transmission module failed or the wrong pluggable transmission module was inserted into an unprotected socket - SA. A protected pluggable transmission module failed or the wrong pluggable transmission module was inserted into a protected socket - NSA. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively), a continuously lighted Fault LED on the failed pluggable transmission module socket, and a flashing Fault LED on the circuit pack. |
Action |
Proceed to Procedure 5-143: Clear "unexpected or failed Pluggable Transmission Module" alarm. |