Specified Pluggable Transmission Module was removed from the circuit pack.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) SA Default: Critical (CR) NSA Default: Minor (MN) |
|
ASAP Type |
Pluggable Transmission Module |
|
AID Type |
Socket |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
FACTERM (Facility termination equipment failure) |
|
Effect on Service |
SA or NSA |
|
Alarm Entity Type |
EQPT |
|
Description |
Pluggable Transmission Module removed |
|
Likely Cause |
An unprotected pluggable transmission module was removed from the circuit pack- SA. A protected pluggable transmission module was removed from the circuit pack - NSA. |
|
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively), a continuously lighted Fault LED on the empty pluggable transmission module socket, and a flashing Fault LED on the circuit pack. |
|
Action |
Proceed to Procedure 5-111: Clear "Pluggable Transmission Module removed" alarm. |