The system has detected a backward defect indicator (BDI) on an incoming 10G optical channel transport unit (OTU2) signal, indicating that the far-end network element has detected incoming OTU2 signal failure.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Not Alarmed (NA) |
ASAP Type |
OTU2 Port |
AID Type |
OTU2 port |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
BDI (Backward Defect Indication) |
Effect on Service |
NSA |
Alarm Entity Type |
OTU2 |
Description |
inc. OTU2 BDI |
Likely Cause |
An incoming OTU2 signal failure was detected at the far-end network element. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
Action |
Proceed to Procedure 5-11: Clear "inc. BDI" alarms. |