inc. OTU2 BDI

Description

The system has detected a backward defect indicator (BDI) on an incoming 10G optical channel transport unit (OTU2) signal, indicating that the far-end network element has detected incoming OTU2 signal failure.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Not Alarmed (NA)

ASAP Type

OTU2 Port

AID Type

OTU2 port

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

BDI (Backward Defect Indication)

Effect on Service

NSA

Alarm Entity Type

OTU2

Description

inc. OTU2 BDI

Likely Cause

An incoming OTU2 signal failure was detected at the far-end network element.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively)

Action

Proceed to Procedure 5-11: Clear "inc. BDI" alarms.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.