The during automatic ring discovery, the ring map could not be completed because of a DCC communications failure.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Minor (Mn) |
|
ASAP Type |
BLSR Protection Group |
|
AID Type |
BLSR protection group |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
RNG-DSCVY (Ring Discovery) |
|
Effect on Service |
NSA |
|
Alarm Entity Type |
COM |
|
Description |
Ring Comm Failure |
|
Likely Cause |
During auto discovery, the ring map could not be completed because of a DCC communication failure. |
|
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
|
Action |
Proceed to Procedure 5-121: Clear "Ring Comm Failure" alarm. |