During BLSR automatic ring discovery, the ring map could not be completed. The network element tries continuously, at 1-minute intervals, to establish a correct ring topology.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Major (MJ) |
ASAP Type |
BLSR Protection Group |
AID Type |
BLSR protection group |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
RNG-INC (Ring Incomplete) |
Effect on Service |
NSA |
Alarm Entity Type |
COM |
Description |
Ring Incomplete |
Likely Cause |
Manual ring map provisioning was not applied or was the ring map was not provisioned correctly. During BLSR auto ring discovery, the ring map could not be completed, because |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) |
Action |
Proceed to Procedure 5-122: Clear "Ring Incomplete" alarm. |