The system cannot communicate with the far-end system through the SONET section data communications channel (DCC).
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Minor (MN) |
|
ASAP Type |
OCn Port |
|
AID Type |
Section Data Communications Channel (DCC) |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
EOC (EOC failure) |
|
Effect on Service |
NSA |
|
Alarm Entity Type |
COM |
|
Description |
section DCC channel failed |
|
Likely Cause |
SYSCTL circuit pack failed, reset, or initialized at the far-end The program installation failed at the far-end The program installation is in progress at the far-end The OC-N OLIU circuit pack failed at the near-end |
|
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack. |
|
Action |
Proceed to Procedure 5-130: Clear "section DCC channel failed" alarm. |
| November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |