section DCC channel failed

Description

The system cannot communicate with the far-end system through the SONET section data communications channel (DCC).

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Minor (MN)

ASAP Type

OCn Port

AID Type

Section Data Communications Channel (DCC)

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

EOC (EOC failure)

Effect on Service

NSA

Alarm Entity Type

COM

Description

section DCC channel failed

Likely Cause

SYSCTL circuit pack failed, reset, or initialized at the far-end

The program installation failed at the far-end

The program installation is in progress at the far-end

The OC-N OLIU circuit pack failed at the near-end

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a flashing Fault LED on the alarmed circuit pack.

Action

Proceed to Procedure 5-130: Clear "section DCC channel failed" alarm.