Squelch Map Inconsistent

Description

Provisioned source and destination (loca/locz) value does not match other provisioned loca/locz values on other cross-connects that are part of circuit.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Minor (MN)

ASAP Type

BLSR Protection Group

AID Type

STS-n Ring Channel

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

SQMAP-INCST (Squelch Map Inconsistent)

Effect on Service

NSA

Alarm Entity Type

COM

Description

Squelch Map Inconsistent

Likely Cause

User selected Configuration → Equipment, selected the Ptn Grp, selected a 2F BLSR protection group and provisioned the Auto Squelch Map to Manual and incorrectly provisioned the loca/locz parameters on one or more cross-connections in the circuit.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively)

Action

Proceed to Procedure 5-131: Clear "Squelch Map Inconsistent" alarm.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.