An internal equipment failure of the SYSCTL circuit pack. While this alarm is present, some types of failures cannot be reported because the SYSCTL circuit pack cannot function under these conditions.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) NSA Default: Minor (MN) |
ASAP Type |
Circuit pack |
AID Type |
Slot |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
CONTR (Control processor failure) |
Effect on Service |
NSA |
Alarm Entity Type |
EQPT |
Description |
SYSCTL CP failed |
Likely Cause |
Internal equipment failure of the SYSCTL circuit pack. |
Visible Indication |
None or lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively). |
Action |
Proceed to Procedure 5-13: Clear "CP failed/CP contributing to a pack failure" alarms. |