This alarm indicates that a different but supported circuit pack is inserted into a slot that is provisioned for another circuit pack type.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) SA Default: Critical (CR) NSA Default: Minor (MN) |
|
ASAP Type |
Circuit pack |
|
AID Type |
Slot |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
FACTERM (Facility termination equipment failure) |
|
Effect on Service |
SA or NSA |
|
Alarm Entity Type |
EQPT |
|
Description |
unexpected CP type |
|
Likely Cause |
The wrong circuit pack was inserted into an unprotected slot. - SA. The wrong circuit pack was inserted into a protected slot - NSA. |
|
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the affected circuit pack. |
|
Action |
Proceed to Procedure 5-142: Clear "unexpected CP type" alarm. |