unexpected CP type

Description

This alarm indicates that a different but supported circuit pack is inserted into a slot that is provisioned for another circuit pack type.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

SA Default: Critical (CR)

NSA Default: Minor (MN)

ASAP Type

Circuit pack

AID Type

Slot

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

FACTERM (Facility termination equipment failure)

Effect on Service

SA or NSA

Alarm Entity Type

EQPT

Description

unexpected CP type

Likely Cause

The wrong circuit pack was inserted into an unprotected slot. - SA.

The wrong circuit pack was inserted into a protected slot - NSA.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the affected circuit pack.

Action

Proceed to Procedure 5-142: Clear "unexpected CP type" alarm.