version mismatch

Description

The firmware in the indicated circuit pack does not match the active software generic running on the network element.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

Default: Minor (MN)

ASAP Type

Circuit pack

AID Type

Slot

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

FACTERM (Facility termination equipment failure)

Effect on Service

NSA

Alarm Entity Type

EQPT

Description

version mismatch

Likely Cause

A circuit pack with a newer version of firmware was installed in a shelf and did not update automatically.

A new circuit pack was inserted into the shelf, the software generic in the dormant area of the SYSCTL was corrupted or did not match the generic running on the shelf, and the firmware did not update automatically.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the alarmed circuit pack.

Action

Proceed to Procedure 5-148: Clear "version mismatch" alarm.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.