The firmware in the indicated circuit pack does not match the active software generic running on the network element.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Minor (MN) |
ASAP Type |
Circuit pack |
AID Type |
Slot |
Date |
Month/day/year that the condition was detected |
Time |
Hour:minute:second that the condition was detected |
Probable Cause |
FACTERM (Facility termination equipment failure) |
Effect on Service |
NSA |
Alarm Entity Type |
EQPT |
Description |
version mismatch |
Likely Cause |
A circuit pack with a newer version of firmware was installed in a shelf and did not update automatically. A new circuit pack was inserted into the shelf, the software generic in the dormant area of the SYSCTL was corrupted or did not match the generic running on the shelf, and the firmware did not update automatically. |
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively) and a continuously lighted Fault LED on the alarmed circuit pack. |
Action |
Proceed to Procedure 5-148: Clear "version mismatch" alarm. |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |