inc. VT AIS

Description

The system has detected a virtual tributary (VT) path alarm indication signal (AIS) incoming from the active OC-N line. The system responds by transmitting DS1 AIS toward the DSX-1 and VT RFI-V back toward the fiber where the AIS is being received.

Alarm Data

Value/Meaning

Severity Levels

Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR)

SA Default: Major (MJ)

NSA Default: Minor (MN)

ASAP Type

VT1.5 Ring Channel

AID Type

VT1.5 Ring Channel

Date

Month/day/year that the condition was detected

Time

Hour:minute:second that the condition was detected

Probable Cause

AIS (AIS detected)

Effect on Service

SA or NSA

Alarm Entity Type

VT1

Description

inc. VT AIS

Likely Cause

Incomplete or incorrect cross-connect provisioning in end-to-end network; unprotected removal or failure of a DS1 circuit pack at the far-end.

In ring applications, a non-service affecting VT AIS alarm message may result from an upstream OLIU or fiber failure affecting only one ring direction. A VT RFI-V alarm message is not returned for a non-service affecting VT AIS.

Visible Indication

Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively)

Action

Proceed to Procedure 5-79: Clear "inc. VT" conditions/alarms.

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.