Alcatel-Lucent 1665 DMXtend meets Telcordia ® Network Equipment Building System "NEBS Generic Equipment Requirements," GR-63-CORE requirements for use in CO environments.
A Fan Assembly is required above the standard Alcatel-Lucent 1665 DMXtend shelf in any environment except an outside cabinet (with ventilation) application. The Alcatel-Lucent 1665 DMXtend High-Capacity shelf has a fan unit built into the bottom of the shelf. The Alcatel-Lucent 1665 DMXtend High-Capacity shelf has a fan unit built into the right side of the shelf.
Alcatel-Lucent 1665 DMXtend is environmentally hardened and will function at temperatures of −40ºC to +65ºC and humidity of 5 to 95 percent (noncondensing) in all TDM applications when equipped with the following circuit packs:
LNW2, LNW7, LNW8, LNW16, LNW18, LNW19B, LNW20, LNW37, LNW39, LNW40, LNW45, LNW49, LNW51, LNW55, LNW63, LNW64, LNW74, LNW84, LNW141, LNW382, LNW391, LNW601, LNW801, or LNW910.
In all other applications, Alcatel-Lucent 1665 DMXtend functions at temperatures of 0ºC to +50ºC.
Alcatel-Lucent 1665 DMXtend has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residence is likely to cause harmful interference in which case the user will be required to correct the interference at the user's own expense.
Alcatel-Lucent 1665 DMXtend meets the earthquake requirements defined in Telcordia ® GR-63-CORE and Pacific Bell Standard PBS-000-102PT.
Alcatel-Lucent 1665 DMXtend meets ignitability requirements specified in ANSI T1.307-1997. In addition, Alcatel-Lucent 1665 DMXtend meets the fire resistance requirements of UL 60950, 3rd Edition.
Alcatel-Lucent 1665 DMXtend is UL recognized for restricted access installations in business and customer premises applications installed in accordance with Articles 110–16 and 110–17 of the National Electric Code, ANSI/NFPA Number 70–87. Other installations exempt from the requirements of the National Electric Code may be engineered according to the accepted practices of the local telecommunications utility.
Alcatel-Lucent 1665 DMXtend has been certified by the Canadian Standards Association per standard CAN/CSA-C22.2 Number 60950-00.