Use this procedure to change an existing unprotected 1+1, Bidirectional 1+1, or UPSR application to an 0x1S1 or 0x1S2 application when the Main slots are not equipped with Very Large Fabric LNW84 or LNW141 OLIU circuit packs.
This procedure allows you to change an existing unprotected application, implemented using prescribed methods prior to Release 3.0, to an 0x1S1 or 0x1S2 application.
Existing 1+1, Bidirectional 1+1, or UPSR applications may be changed to 0x1S1 or 0x1S2 applications if the following conditions are met:
There are no cross-connections to UPSR ring channels. Cross-connections on 0x1Sn ports are provisioned only with channel aids.
There are no unswitched cross-connections on UPSR ports. Unswitched cross-connections are not supported on 0x1Sn ports.
Service for all provisioned cross-connections on the port(s) is carried on the port in slot n.
Complete the following steps to change provisioning for the required port.