Procedure 11-39: Enable/Disable transmission audit

- Overview

Use this procedure to enable or disable transmission audit on the LNW70/LNW170 circuit packs.

The transmission audit is a consistency check between counters on various devices on the LNW70/LNW170 circuit pack. The transmission audit feature provides error detection capabilities that might not otherwise be detected.

When enabled, a transmission audit failure will result in a LAN or VCG segment audit failed alarm (SEGAUDTIN or SEGAUDTOUT) or equipment NP audit failed alarm (NPAUDT). When transmission audit is disabled, any outstanding NPAUDT and SEGAUDTIN/SEGAUDTOUT alarms clear.

When transmission audit is enabled for a circuit pack that is part of a pair of protected circuit packs (LNW170 only), transmission audit is enabled for both circuit packs of the pair.

- Privilege level

You must login at least as a General or Privileged user to complete this procedure.

- Before you begin

Prior to performing this procedure, refer to Before you begin and Required equipment in this chapter and you must have complete work instructions for this procedure that detail the shelf slots and circuit packs that are being enabled/disabled.

Steps

Use the following procedure to enable/disable transmission audit.

 
1

Use the WaveStar® CIT to log in to the Alcatel-Lucent 1665 DMXtend shelf.

Reference:

Procedure 14-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


2

Select Configuration → Equipment from the System View menu. Select the circuit pack, then click Select.


3

For Transmission audit, select ENABLED (default value) to enable transmission audit. Select DISABLED to disable transmission audit. Click Apply, read the warning message, then click Yes to execute the command. Click Close to exit.


End of steps