Port parameters

The following table shows the provisionable port parameters.

Table A-1: Port parameters

Parameter

TL1 Commands (Access) (Note)

Range

Default

Related WaveStar® CIT Commands

BPV to All Zeroes Translation on Incoming DS1 (bpv) 1

ENT-T1

(P, G)

N,Y

N

Configuration → Equipment

DS1 Incoming Signal Format (fmt)

SF, ESF, ESFN, UF

ESF

DS1 Line Code (linecde)1

AMI, B8ZS

AMI

DS1 Line Buildout (lbo)1

20 (0–133 ft.),

40 (133–267 ft.),

60 (267–420 ft.),

80 (420–550 ft.),

100 (550–655 ft.)

20

Interface Type (intftype)

ED-EQPT

(P, G)

E1, DS1

E1 Signal Format (fmt)

ENT-E1

(P, G)

FAS, CRC4

CRC4

DS3 AIS

ENT-T3

(P, G)

Y, N

N

DS3/EC1 Mode (eif)

LNW19/19B and LNW20 only

LNW16: Hardware Settable

ENT-T3 ENT-EC1

(P, G)

DS3, EC1

DS3

Line Buildout (lbo)

ENT-EC1

ENT-T3

(P, G)

728A/B Cable:

IN (0–225),

OUT (225–450)

735A Cable:

IN (0–112),

OUT (112–225)

IN

Configuration → Equipment

DS3 Line Coding (linecde)

ENT-T3

(P, G)

B3ZS, CCHAN1

B3ZS

DS3 Frame Format (frame)

M13, CBIT, CCHAN1

M13

P-bit Violation Removal (pbit)

ON, OFF

ON

DS3 Incoming Signal Format (fmt)

PBIT, FMBIT, CPBIT

PBIT

TCA Monitoring Mode (tcamd)

ENT-E1

ENT-T1

ENT-T3

ENT-EC1

ENT-OC3

ENT-OC12

ENT-OC48

ENT-OC192

ENT-OCH

ENT-OTS

ENT-OTU2

(P, G)

ENABLE, DISABLE

ENABLE

Performance → Prov PM Settings

Alarm Severity Assignment Profile (pfname)

ENT-ASAP-ASGNMT

(P, G)

DEFAULT ASAP

User-Created ASAP

DEFAULT ASAP

Configuration → Equipment

Primary State (pst)

ENT-E1

ENT-T1

ENT-T3

ENT-EC1

ENT-OC3

ENT-OC12

ENT-OC48

ENT-OC192

ENT-OCH

ENT-OTS

ENT-OTU2

(P, G)

OOS (NMON)

OOS-MA-AS (AUTO)

IS (In Service)

AUTO

Configuration → Equipment

Signal Failure Threshold (sfthr)

ENT-E1

ENT-T1

ENT-T3

ENT-EC1

(P, G)

-3, -6, -7, -8

-3, -6, -7, -8

-4, -6

-3, -5, -6, -7, -8, -9

-3

-3

-6

-6

ENT-OC3

ENT-OC12

ENT-OC48

ENT-OC192

(P, G)

-5, -6, -7, -8, -9

-6

Signal Fail Threshold (sfail)

ENT-OC3

ENT-OC12

ENT-OC48

ENT-OC192

(P, G)

-3, -4, -5

-3

PJC Monitor Point (pjcmon)

ENT-OC3

ENT-OC12

ENT-OC48

ENT-OC192

(P, G)

N (number of STSn tributary),

AUTO

AUTO-NO-TCA

AUTO-NO-TCA

Performance → Prov PM Settings

Transmission Protection (application)

(low-speed slots)

ENT-OC3

ENT-OC12

ENT-OC48

(P, G)

0x1S1 (non-VLF Mains), 0x1S2 (non-VLF Mains), 0x1 (VLF Mains), 1+1, 1+1_BIDIR, UPSR

1+1

Configuration → Equipment

Transmission Protection (application)

(high-speed slots)

ENT-OC3

ENT-OC12

ENT-OC48

ENT-OC192

(P, G)

UPSR, 1+1, 1+1_BIDIR

0x1 (VLF Mains only)

UPSR

Transmission Protection (application)

(LNW705 XM10G/8 circuit pack client ports only)

ENT-OC3

ENT-OC12

ENT-OC48

(P, G)

0x1

0x1

Socket Maintenance State (mst)

ED-EQPT

(P, G)

Normal, Maintenance

Normal

Expected DWDM Frequency (efreq)

NA

9200 to 9590 in increments of 10

Auto

NA

Default Port Maintenance (portmntc_default)

ENT-SYS

(P)

Allow, Inhibit

Allow

Configuration → Equipment

PDH port Equipment Fault Control (pdheqfltctl)

Enabled, Disabled

Disabled

Transmit Section Trace Format (strcwfmt)

Expected Receive Section Trace Format (strcfmt)

ENT-EC1

ENT-OC3

ENT-OC12

ENT-OC48

ENT-OC192

(P, G)

EC-1: 1, 2

OC-3/12/48/192: 1, 2, 16, 64

2

Transmit Section Trace Value - Hexadecimal (strcout)

Expected Receive Section Trace Value - Hexadecimal (exprstrc)

characters 0–9 and A–F in a string up to twice the number specified by the format

Format 1=00

Format 16=89

Format 64=C8

Transmit Section Trace Value - ASCII (strcouttxt)

Expected Receive Section Trace Value - ASCII (exprstrctxt)

ENT-EC1

ENT-OC3

ENT-OC12

ENT-OC48

ENT-OC192

(P, G)

Any characters except semicolon, double quote, and backslash.

Format 1=1 character

Format 16 =15 characters

Format 64=63 characters

Null

Configuration → Equipment

Receive Section Trace Identifier Monitor (rstimmon)

Enable, Disable

Disable

Receive Section Trace Identifier Mismatch Consequent Action (rstimca)

Enable, Disable

Disable

Port Mode (pmd)

(LNW20 only)

ENT-T3

(P, G)

PORTED, PORTLESS (odd ports only with non-VLF Mains, all ports with VLF Mains)

PORTED

Configuration → Equipment

Tributary Mode (tribmod)

(LNW20 only)

ENT-T3

(P, G)

UNCHAN, CHAN

UNCHAN

Signal Type (signaltype)

ENT-STNA

ENT-OC3

ENT-OC12

ENT-OC48

(P, G)

STNA, OC3, OC12, OC48

STNA (No expected circuit pack type or unprotected companion), or

Same value as protected companion

Signal Type (signaltype) (LNW705 client ports only)

ENT-OTPE

(P, G)

STNA, OC3, OC12, OC48, 1GE, FC100, FC200, FICON, FICON_EXP

STNA

Configuration → Equipment

Forward Error Correction Type (fectype)

ENT-OTU2

(P, G)

EFEC: Enhanced FEC

NOFEC: No FEC

RSFEC: Industry-standard Reed-Solomon FEC

EFEC

Transmit Fiber Type (tx_ftype)

ENT-OTS

(P, G)

SSMF: not provisionable

SSMF

Receive Fiber Type (rx_ftype)

SS Bits (ssbits) (port level)

(LNW55, LNW62, LNW84, and LNW141 only)

ENT-OC3

ENT-OC12

ENT-OC48

ENT-OC192

(P, G)

SS00, SS10

SS00

1Does not apply to the TMUX circuit pack.

Note: The TL1 command security access levels are Privileged (P), Administration (A), General (G), Maintenance (M), and Reports-only (R).

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.