The network element cannot establish communication with the designated alarm gateway network element (AGNE), or the AGNE cannot establish communication with a network element in the same alarm group, or the AGNE has lost communication with a network element in the same alarm group.
|
Alarm Data |
Value/Meaning |
|---|---|
|
Severity Levels |
Critical (CR), Major (MJ), Minor (MN), Not Alarmed (NA), Not Reported (NR) Default: Major (MJ) |
|
ASAP Type |
System |
|
AID Type |
Blank |
|
Date |
Month/day/year that the condition was detected |
|
Time |
Hour:minute:second that the condition was detected |
|
Probable Cause |
PRCDRERR (Procedure error) |
|
Effect on Service |
NSA |
|
Alarm Entity Type |
COM |
|
Description |
AGNE communication failure |
|
Likely Cause |
Either the AGNE has not been provisioned or has failed. |
|
Visible Indication |
Lighted CR, MJ, or MN LED on the SYSCTL faceplate (when the severity level is provisioned to Critical, Major, or Minor, respectively). |
|
Action |
Proceed to Procedure 5-3: Clear "AGNE communication failure" alarm. |
| November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |