Procedure 5-5: Clear "AUTO link shutdown" alarm

- Overview

This procedure is used to clear an AUTO link shutdown alarm.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear an AUTO link shutdown alarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the AUTO link shutdown alarm in the resulting alarm list.


2

Important!

The AUTO link shutdown alarm is reported when the local network element detects a remote client signal fail message from the far-end network element or a VCG failure occurs and the local port Remote Client Fail Link Shutdown parameter is Enabled.

Important!

For FE and GE ports on the LNW63, LNW64, LNW74, LNW87, and LNW70/LNW170 packs, the AUTO link shutdown alarm is also reported when the local network element detects a remote GFP RDI message from the far-end network element and both the local port Remote Client Fail Reverse Defect Indication and the local port Remote Client Fail Link Shutdown parameters are enabled.

Remote GFP RDI messages are received when the far-end network element has a VCG failure while the Remote Client Fail Reverse Defect Indication and the Remote Client Fail parameters are enabled.

Locate and clear all Remote client signal failed and inc. VCG failed alarms in the alarm list.

Reference:


3

From the System View, click the Alarm List button and click Refresh.

If the AUTO link shutdown alarm is still present, contact your next level of support.


End of steps