Procedure 5-95: Clear "Protection switching channel match failure" alarm

- Overview

This procedure is used to clear a Protection switching channel match failure alarm.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear a Protection switching channel match failure alarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the Protection switching channel match failure alarm in the resulting alarm list and note the corresponding AID.


2

Refer to office records to determine the correct provisioning for the port Application parameter of the applicable optical port pair. (The port Application parameter of the applicable local optical port pair is currently provisioned Bidirectional 1+1 or Optimized 1+1.)


3

To clear the Protection switching channel match failure alarm either change the port Application parameter of the applicable local port pair or change the port Application parameter of the applicable far-end port pair according to office records and local procedures.

If changing the port Application parameter of the...

Then...

far-end optical port pair,

notify personnel at the site supplying the optical signal to change the port Application parameter according to office records.

STOP! End of procedure.

local optical port pair,

go to the next step.


4

From the System View, select Configuration → Equipment to access the required port and provision the port Application parameter according to office records.


End of steps