Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear an inc. EC1 alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the inc. EC1 alarm in the resulting alarm list. | ||||||
2 |
Determine the alarm level(s) for the active inc. EC1 alarm(s). Clear the alarms in order of severity. | ||||||
3 |
Refer to the Probable Cause column in the alarm list, determine the affected port, and note the corresponding AID. | ||||||
4 |
Check cable connections between the shelf and the cross-connect panel (or equivalent) for faulty connections/damage and repair/replace as necessary. | ||||||
5 |
From the System View, click the Alarm List button and click Refresh. | ||||||
6 |
Is the inc. EC1 alarm still present?
| ||||||
7 |
Important! A likely cause of an inc. EC1 alarm at the local network element is a failure at the interfacing customer EC1 port or a problem with the cabling/wiring between systems. Follow local procedures to isolate and clear the trouble. End of steps |