Procedure 5-22: Clear "EC1 loopback (to DSX)" condition

- Overview

This procedure is used to clear an EC1 loopback (to DSX) condition. The condition indicates that a user initiated an EC-1 facility loopback.

Important!

Proper terminating and pass through cross-connections must exist at each shelf (including stand-alone shelves) to establish continuity for the EC-1 circuit being tested.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear an EC1 loopback (to DSX) condition.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the EC1 loopback (to DSX) condition in the resulting alarm list.


2

Refer to the Probable Cause column in the alarm list, and note the corresponding AID.


3

From the System View, select Fault → Analysis → Loopback, expand the appropriate circuit pack, select the affected EC-1 port, and click Select.

Result:

The Loopback window opens.


4

From the Loopback screen, select Facility and Release. Click Apply.

Result:

A warning message appears asking you to confirm executing this command. Click Yes and Close.


End of steps