Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear an ENET loopback condition.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the ENET loopback condition in the resulting alarm list. |
2 |
Refer to the Probable Cause column in the alarm list, and note the corresponding AID. |
3 |
From the System View, select Fault → Analysis → Loopback and expand the appropriate Ethernet circuit pack. Select the affected AID and click Select. Result: The Loopback window opens. |
4 |
From the Loopback screen, click Release and Apply. Result: A warning message appears asking you to confirm executing this command. Click Yes and Close. End of steps |