Procedure 5-28: Clear "ERP - Multiple RPL Owners" alarm

- Overview

This procedure is used to clear an ERP - Multiple RPL Owners alarm.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.

  3. Obtain office records identifying the nodes in the ring and the correct Ethernet ring protection RPL ID provisioning.

Steps

Complete the following steps to clear an ERP - Multiple RPL Owners alarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the ERP - Multiple RPL Owners alarm in the resulting alarm list and note the corresponding AID.


2

Important!

Only one RPL owner node is allowed in the ring.

Using office records determine which node in the ring is the RPL owner node.


3

Log in to each node in the ring one at a time and verify that the RPL ID parameter is provisioned correctly.

If the node is a...

Then...

Alcatel-Lucent 1665 DMXtend

From the System View, select View → Data → ERP and the required Ethernet circuit pack to obtain Ethernet ring protection provisioning.

If required, select Configuration → Data → Create/Modify/Delete ERP and the required Ethernet circuit pack/ring to reprovision the RPL ID parameter.

another product,

Use product's documentation to log in and obtain the required port/VCG Ethernet ring protection provisioning.

If required reprovision the RPL ID parameter.

Reference:

Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session


End of steps

November 2011Copyright © 2011 Alcatel-Lucent. All rights reserved.