Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Obtain office records identifying the nodes in the ring and the correct Ethernet ring protection RPL ID provisioning.
Complete the following steps to clear an ERP - Multiple RPL Owners alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the ERP - Multiple RPL Owners alarm in the resulting alarm list and note the corresponding AID. | ||||||
2 |
Important! Only one RPL owner node is allowed in the ring. Using office records determine which node in the ring is the RPL owner node. | ||||||
3 |
Log in to each node in the ring one at a time and verify that the RPL ID parameter is provisioned correctly.
Reference: Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session End of steps |