Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear a Member Not Collecting/Distributing alarm.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the Member Not Collecting/Distributing alarm in the resulting alarm list. | ||||||
2 |
Refer to the Probable Cause column in the alarm list, determine the affected LAN port, and note the corresponding LAN port AID. | ||||||
3 |
Important! A likely cause of the Member Not Collecting/Distributing alarm at the local network element is a configuration conflict with the interfacing customer LAN port (LAG partner). The Link Aggregation Group and/or LAN port provisioning at the interfacing customer equipment is incompatible. Follow local procedures for addressing configuration conflicts at the interfacing customer equipment. | ||||||
4 |
From the System View, click the Alarm List button and click Refresh. | ||||||
5 |
Is the Member Not Collecting/Distributing alarm still present?
| ||||||
6 |
From the System View menu, select Configuration → Data → Create/Modify/Delete LA Group to access the required local Link Aggregation Group and provision the Protocol parameter to None to disable the Link Aggregation Control Protocol and enable forced aggregation. | ||||||
7 |
From the System View, click the Alarm List button and click Refresh. If the Member Not Collecting/Distributing alarm is still present, contact your next level of support. End of steps |