Procedure 5-78: Clear "manual reference switch" condition

- Overview

This procedure is used to clear a manual reference switch condition.

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear a manual reference switch condition.

 
1

From the System View, select Fault → Timing/Sync Protection Switch → System Timing Reference/Source Switch, select Reset, and click OK.

Result:

A warning message appears asking you to confirm executing this command. Click Yes.


2

From the System View, click the Alarm List button and click Refresh.

Result:

The manual reference switch condition is no longer present.


End of steps