Complete the following steps to clear generic and database alarms.
1 |
Important! When the network element is in the Maintenance Mode state, the IND display on the SYSCTL circuit pack faceplate shows MPx.x (where x.x is the generic number). If the network element is in the Maintenance Mode state, the default User IDs/passwords must be used to log in to the network element. LUC01, LUC02, and LUC03 are the default privileged User IDs, and DMXTND2.5G is the default privileged password. Log in to the network element. Result: The Maintenance Mode Wizard (Screen 1 of 4) appears. Reference: Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session |
2 |
Perform the following to choose/download and install the required valid generic and database.
Result: The system resets and you are logged off the system. A flashing b in the IND display on the SYSCTL indicates that a boot is in progress. During the boot, the b may extinguish for up to 20 seconds and then resume flashing. Reference: |
3 |
Important! If a default database was selected/installed, the default User IDs/passwords must be used to log in to the network element. LUC01, LUC02, and LUC03 are the default privileged User IDs, and DMXTND2.5G is the default privileged password. If a valid (non-default) database was selected/installed, the provisioned User IDs/passwords may be used to log in to the network element. When the system reset is complete, log back into the network element. Reference: Procedure 6-2: Connect Personal Computer (PC) and establish WaveStar® CIT session |
4 |
If a default database was selected/installed, restore the most recent network element database using the Configuration → Software → Remote Restore command, if required. Reference: End of steps |
November 2011 | Copyright © 2011 Alcatel-Lucent. All rights reserved. |