DS1/E1 (VLNC50, VLNC52, VLNC55, VLNC60, VLNC61, VLNC62, and VLNC64)

Purpose

The DS1/E1 tributary interfaces transmit and receive a standard electrical DS1/E1 signal. DS1 signals are as specified in GR-499-CORE (1.544 Mb/s nominal rate, DSX-1 interconnect specification). E1 signals are as specified in ITU G.703, G.704, G.706, G.736, G.775, M.2100 (120-Ohm termination, 2.048 Mb/s nominal rate, DSX-1 interconnect specification).

DS1 format specification

The VLNC50, VLNC52, VLNC55, VLNC60, VLNC61, VLNC62, and VLNC64 framing format can be set to SF, ESF, and UF (unframed) for the DS1 ports. Interfaces used in ML-PPP mode cannot be unframed. DS1 line coding (VLNC50/52/55 and VLNC60/61/62) is provisioned per DS1 port to alternate mark inversion (AMI) or AMI with bipolar 8-zero substitution (B8ZS).

E1 format specification

The VLNC50, VLNC52, VLNC55, VLNC60, VLNC61, VLNC62, and VLNC64 framing format can be set to FAS or CRC-4, and a line code of HDB3.

Alarms

The following parameters are monitored on the VLNC50, VLNC52, VLNC55, VLNC60, VLNC61, VLNC62, and VLNC64 DS1/E1 interfaces:

The alarm level for the monitored parameters can be provisioned to critical (CR), major (MJ), minor (MN), or status.

Coding violation failure thresholds are provisionable.

DS1/E1 transmission length

When transmitting the DS1/E1 signals to a DSX panel, the Approximate Span Length is 655 feet.

Loopbacks

The following loopbacks are supported on the VLNC50, VLNC52, VLNC55, VLNC60, VLNC61, VLNC62 circuit packs:

The following loopbacks are supported on the VLNC64 circuit pack:

Line build-outs (LBOs)

Line build-outs are software-provisionable for VLNC50, VLNC52, VLNC55, VLNC60, VLNC61, VLNC62; LBOs do not apply to the portless VLNC64 packs. The maximum distance depends on the cable type. The maximum cable length for DS1/E1 lines is 655 feet.

Performance monitoring

For a detailed list of PM parameters and thresholds, refer to DS1 performance monitoring parameters and E1 performance parameters in Chapter 5, Operations, administration, maintenance, and provisioning.

Copyright © 2011 Alcatel-Lucent. All rights reserved.