Environmental specifications

Temperature and humidity

Alcatel-Lucent 1850 TSS-5 is environmentally (OSP, Outside Plant) hardened and will function at temperatures of −40°C to +65°C and humidity of 5 to 95 percent (non-condensing) in all TDM and Ethernet applications when equipped with the VLNC2, VLNC33, VLNC35, VLNC40, VLNC42/42B, VLNC50, VLNC52, VLNC55, VLNC60, VLNC61, VLNC62, and VLNC64 circuit packs.

Therefore, the Alcatel-Lucent 1850 TSS-5 shelf meets Telcordia ® Network Equipment Building System (NEBS Generic Equipment Requirements, GR-63-CORE) requirements for use in CO environments.

EMI compliance

Alcatel-Lucent 1850 TSS-5 complies with the limits for a Class A device, in accordance with Part 15 of the FCC rules and Telcordia ® GR-1089-CORE. These limits provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy. This equipment must be installed and operated in accordance with the instruction manual, to avoid interference to radio communications. This equipment is not designed for installation in a residence location. The user assumes responsibility for EMI interference, resulting from improper installation.

Earthquake requirements

Alcatel-Lucent 1850 TSS-5 meets the earthquake requirements defined in Telcordia ® GR-63-CORE and Pacific Bell Standard PBS-000-102PT.

Fire resistance

Alcatel-Lucent 1850 TSS-5 meets flammability requirements specified in ANSI T1.307-1997. In addition, the Alcatel-Lucent 1850 TSS-5 meets the fire resistance requirements of UL 60950, 3rd Edition and Telcordia ® GR-63, Issue 2, April 2002.

Safety

Alcatel-Lucent 1850 TSS-5 complies with CSA-C22.2 No. 60950-00, and UL60950-00 Safety of information technology equipment.

Alcatel-Lucent 1850 TSS-5 is UL recognized for restricted access installations in business and customer premises applications installed in accordance with Articles 110-16 and 110-17 of the National Electric Code, ANSI/NFPA Number 70-87. Other installations, exempt from the requirements of the National Electric Code, may be engineered according to the accepted practices of the local telecommunications utility.

Canadian Standards Association

Alcatel-Lucent 1850 TSS-5 has been certified by the Canadian Standards Association per standard CAN/CSA-C22.2 Number 60950-00.