Port parameters

The following table shows the provisionable port parameters.

Table A-1: Port parameters

Parameter

TL1 Commands (Access) (Note)

Range

Default

Related WaveStar® CIT Commands

DS1 Incoming Signal Format (fmt)

ENT-T1

(P, G)

SF, ESF, ESFN, UF

ESF

Configuration → Equipment

DS1 Line Code (linecde)

AMI, B8ZS

B8ZS

DS1 Line Buildout (lbo)

20 (0-133 ft.),

40 (133-267 ft.),

60 (267-420 ft.),

80 (420-550 ft.),

100 (550-655 ft.)

20

DS1 inband loopback from DSX (inbandlpbkdsx)

Enable, Disable

Disable

DS1 inband loopback from fiber (inbandlpbkfiber)

Enable, Disable

Disable

Port Mode (pmd) (DS1 in A group or DS1 in Channelized b-3 DS3)

Avail, Unavail

Avail

E1 Signal Format (fmt)

ENT-E1

(P, G)

FAS, CRC4

CRC4

E1 Line Code (linecde)

HDB3 (not provisionable or retrievable)

HDB3

DS3 AIS

ENT-T3

(P, G)

Y, N

N

Line Buildout (lbo)

ENT-T3

(P, G)

728A/B Cable:

IN (0-225),

OUT (225-450)

735A Cable:

IN (0-112),

OUT (112-225)

IN

Configuration → Equipment

DS3 Line Coding (linecde)

ENT-T3

(P, G)

B3ZS, CCHAN1

B3ZS

Configuration → Equipment

DS3 Frame Format (frame)

M13, CBIT, CCHAN1

M13

P-bit Violation Removal (pbit)

ON, OFF

ON

DS3 Incoming Signal Format (fmt)

PBIT, FMBIT, CPBIT

PBIT

Tributary Mode (tribmd) (b-3 port only)

Unchan, Chan

Unchan

FEAC loopback requests from DSX (feaclpbkdsx) (b-3 port only)

Enable, Disable

Disable

TCA Monitoring Mode (tcamd)

ENT-E1

ENT-T1

ENT-T3

ENT-OC3

ENT-OC12

ENT-OC48

ENT-STM1

ENT-STM4

ENT-STM16

(P, G)

Enable, Disable

Enable

Performance → Prov PM Settings

Incoming Signal Failure Alarm Level (ntfcncde)

ENT-E1

ENT-E3

ENT-T1

ENT-T3

(P, G)

DS1/E1: MJ, MN, NA

DS3/E3: CR, MJ, MN, NA

DS1/E1: NA

DS3/E3: CR

Configuration → Equipment

Signal Failure Threshold (sfthr)

ENT-E1

ENT-T1

(P, G)

-3, -6, -7, -8

-3

ENT-E3

ENT-T3

(P, G)

-4, -6

-6

Primary State (pst)

ENT-E1

ENT-E3

ENT-T1

ENT-T3

(P, G)

OOS-MA-AS (AUTO),

OOS (NMON)

AUTO

Alarm Indication Signal (AIS) Notification for Non-Service Affecting Alarms (aisnc)

ENT-OC3

ENT-OC12

ENT-OC48

ENT-STM1

ENT-STM4

ENT-STM16

(P, G)

CR, MJ, MN, NA

NA

Configuration → Equipment

Line Remote Defect Indicator (rdi-l)

MJ, MN, NA

NA

Signal Degrade Threshold (sfthr)

-5, -6, -7, -8, -9

-6

Signal Fail Threshold (sfail)

-3, -4, -5

-3

PJC Monitor Point (pjcmon)

ENT-OC3

ENT-OC12

ENT-OC48

(P, G)

N (number of STSn tributary to be monitored),

AUTO

AUTO-NO-TCA

AUTO-NO-TCA

Performance → Prov PM Settings

Transmission Protection (application)

ENT-OC3

ENT-OC12

ENT-OC48

(P, G)

UPSR, 1+1, 0x1

0x1

Configuration → Equipment

ENT-STM1

ENT-STM4

ENT-STM16

(P, G)

SNCP, 1+1, 0x1

0x1

Signal Type (signaltype)

ENT-OC3

ENT-OC12

ENT-OC48

(P, G)

OC3, OC12, OC48

OC3

ENT-STM1

ENT-STM4

ENT-STM16

(P, G)

STM1, STM4

STM1

Primary State (pst)

ENT-OC3

ENT-OC12

ENT-OC48

ENT-STM1

ENT-STM4

ENT-STM16

(P, G)

OOS-MA-AS (AUTO),

OOS (NMON)

AUTO

Slot protection state (prot_state)

ED-EQPT

(P, G)

Prot, Unprot

Unprot

Note: The TL1 command security access levels are Privileged (P), Administration (A), General (G), Maintenance (M), and Reports-only (R).

Copyright © 2011 Alcatel-Lucent. All rights reserved.