Cross-connection parameters

The following table shows the provisionable cross-connection parameters.

Table A-4: Cross-connection parameters

Parameter

TL1 Commands (Access) (Note)

Range

Default

Related WaveStar® CIT Commands

VT1.5 Cross-Connect Type (cct)

ENT-CRS-VT1

(P, G)

2waypr (UPSR, 1+1)

2way (0x1, UPSR, Hairpin, Locked)

2waypr

2way

Configuration → Cross-Connections

STS-1 Cross-Connect Type (cct)

ENT-CRS-STS1

(P, G)

2waypr (UPSR, 1+1)

2way (0x1, UPSR, Hairpin)

2waypr

2way

STS-3c Cross-Connect Type (cct)

ENT-CRS-STS3c

(P, G)

2waypr (UPSR, 1+1)

2way (0x1, UPSR, Hairpin)

2waypr

2way

STS-12c Cross-Connect Type (cct)

ENT-CRS-STS12c

(P, G)

2waypr (UPSR, 1+1)

2way (0x1, UPSR, Hairpin)

2waypr

2way

VC-12 Cross-Connect Type (cct)

ENT-CRS-VC12

(P, G)

2waypr (SNCP, 1+1)

2way (0x1, SNCP, Hairpin)

2waypr

2way

VC-3 Cross-Connect Type (cct)

ENT-CRS-VC3

(P, G)

2waypr (SNCP, 1+1)

2way (0x1, SNCP, Hairpin)

2waypr

2way

VC-4 Cross-Connect Type (cct)

ENT-CRS-VC4

(P, G)

2waypr (SNCP, 1+1)

2way (0x1, SNCP, Hairpin)

2waypr

2way

VC-44C Cross-Connect Type (cct)

ENT-CRS-VC44C

(P, G)

2waypr (SNCP, 1+1)

2way (0x1, SNCP, Hairpin)

2waypr

2way

Configuration → Cross-Connections

Circuit ID (circuitid)

ENT-CRS-VT1

ENT-CRS-STS1

ENT-CRS-STS3c

ENT-CRS-STS12c

ED-CRS-VT1

ED-CRS-STS1

ED-CRS-STS3c

ED-CRS-STS12c

ENT-CRS-VC12

ENT-CRS-VC3

ENT-CRS-VC4

ENT-CRS-VC44C

ED-CRS-VC12

ED-CRS-VC3

ED-CRS-VC4

ED-CRS-VC44C

(P, G)

up to 36 ASCII characters

null

Configuration → Cross-Connections

Note: The TL1 command security access levels are Privileged (P), Administration (A), General (G), Maintenance (M), and Reports-only (R).