Use this procedure to provision the following system alarm configuration parameters:
Alarm-Clear Delay
Sets the time in seconds that the system waits before reporting that an alarm condition is cleared. Alarm-Clear Delay only applies to equipment alarms, not to signal failures. Signal failures have a fixed 10-second delay.
Alarm-Generate Delay
Sets the time in seconds that the system waits before reporting an incoming signal alarm condition.
Power Alarm Level: Provisions the alarm level of a power alarm.
Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Obtain the work instructions for this procedure.
Perform the following steps to provision system alarm parameters.
1 |
From the System View menu, select Configuration → Alarms → Alarm Configuration. Result: The Configure Alarms window opens. |
2 |
Provision the Alarm-Clear Delay, Alarm-Generate Delay, and/or Power Alarm Level parameters according to the work instructions and Click OK. End of steps |