underlying resources unavailable, equipment

Description

The NE declares a URU-S failure against each associated STM-n line on a failed circuit pack if a circuit pack failure defect persists for the alarm processing delay period ± 0.5 seconds. Refer to SET-ATTR-ALM:almdel in Alcatel-Lucent 1850 Transport Service Switch (TSS-5) TL1 Command Guide for MSPP. Upon declaring and the failure, the NE sends an alarm message to the appropriate OS(s). The NE clears a URU-S failure when the CP failed defect clears. After clearing the failure, the NE also sends an alarm message to the appropriate OS(s).

Alarm Data

Value/Meaning

Severity Levels

Major (MJ), Minor (MN)

SA: Major (MJ)

NSA: Minor (MN)

AID Type

STMN Line

Date

Month/day/year that condition was detected

Time

Hour:minute:second that condition was detected

Probable Cause

URU-S

Effect on Service

SA or NSA

Alarm Entity Type

STM1

STM4

STM16

Description

underlying resources unavailable, equipment

Likely Cause

The URU-S alarm(s) is declared coincident with a CP failed alarm.

An unprotected circuit pack carrying service failed: MJ: SA.

A protected circuit pack failed or an unprotected circuit pack NOT carrying service failed: MN: NSA.

Visible Indication

Lighted CR/MJ or MN/ABN LED on SYSCTL faceplate and a flashing FAULT LED on the failed circuit pack.

Action

In the alarm list, find the associated CP failed alarm, and proceed to Procedure 5-9: Clear "CP failed" alarms.

Copyright © 2011 Alcatel-Lucent. All rights reserved.