Procedure 5-28: Clear "inc. (from DSX) E3" conditions/alarms

- Overview

This procedure is used to clear the following inc. (from DSX) E3 alarms:

  • inc. (from DSX) E3 AIS

  • inc. (from DSX) E3 LOS

  • inc. (from DSX) E3 sig. failed

- Before you begin

Prior to performing this procedure:

  1. Refer to Before you begin and Required equipment in this chapter.

  2. Refer to Electrostatic discharge in Chapter 1, Safety.

Steps

Complete the following steps to clear an inc. (from DSX) E3 alarm.

 
1

From the WaveStar® CIT System View, click the Alarm List button and locate the inc. (from DSX) E3 alarm in the resulting alarm list.


2

Determine the alarm level(s) for the active inc. (from DSX) E3 alarm(s). Clear the alarms in order of severity.


3

Refer to the Probable Cause column in the alarm list, determine the affected port, and note the corresponding AID.


4

Check cable connections between the access panel and the DSX panel for faulty connections or damage and repair/replace as necessary.


5

From the System View, click the Alarm List button and click Refresh.


6

Is the inc. (from DSX) E3 alarm still present?

If...

Then...

Yes

Continue with the next step.

No

STOP! End of Procedure.


7

Important!

A likely cause of an inc. (from DSX) E3 alarm at the local network element is a failure at the interfacing customer E3 port or a problem with the cabling/wiring between systems.

Follow local procedures to isolate and clear the trouble.


End of steps