Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Laser safety and Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear an incoming CRC-4 MFA mismatch condition.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the incoming CRC-4 MFA mismatch condition in the resulting Alarm List and note the corresponding AID. | ||||||
2 |
To clear the incoming CRC-4 MFA mismatch condition, either change the signal format of the incoming E1 signal to CRC-4 or change the signal format parameter of the local E1 port to Frame Alignment Signal according to local procedures.
| ||||||
3 |
From the System View, select Configuration → Equipment. Expand the group/TUG signals. Select the required E1 port and click Select. Result: The port provisionable parameters appear. | ||||||
4 |
Provision the Signal Format parameter of the E1 port to Frame Alignment Signal and click Apply. Result: A warning message appears asking you to confirm executing this command. Click Yes and Close. End of steps |
Copyright © 2011 Alcatel-Lucent. All rights reserved. |