Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear the install failed condition.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the install failed condition in the resulting alarm list and note the corresponding AID. | ||||||
2 |
Important! A Smart (without Override) or Smart (with Override) software apply operation downloads software to the circuit packs that require updates only. From the System View, select Configuration → Software → Apply Software to schedule a Smart (without Override) or Smart (with Override) software apply operation. Result: Approximately 15 minutes after the scheduled Smart apply time, the apply is complete. You will be logged off the system when the system resets. Reference: Procedure 6-9: Apply software generic | ||||||
3 |
Log back into the network element. From the System View, click the Alarm List button and click Refresh. | ||||||
4 |
Is the install failed condition still present?
| ||||||
5 |
From the System View, select Fault → Reset → System Controller. Result: The Reset System Controller window opens. | ||||||
6 |
Important! Do NOT select Restore the system-level parameters to their default values (Phase 9) on an in-service system. Phase 9 resets all provisionable parameters to the default values and the system controller executes a full power-up sequence. Click Reset the system software without changing parameters (Phase 3). Click OK. Result: A warning appears asking you to confirm executing this command. | ||||||
7 |
Click Yes to execute the command. Result: The system resets and you are logged off the system. | ||||||
8 |
Log back into the network element. From the System View, click the Alarm List button and click Refresh. | ||||||
9 |
Is the install failed condition still present?
| ||||||
10 |
Disconnecting cables and/or replacing circuit packs may disrupt service. Before taking action, determine the extent of service disruption caused by disconnecting cables or replacing a circuit pack. Then, perform the action(s) deemed appropriate in light of the traffic being carried and the nature of the failure. Disengage the affected circuit pack completely from the shelf.
| ||||||
11 |
From the System View, click the Alarm List button and click Refresh. | ||||||
12 |
Is the install failed condition still present?
| ||||||
13 |
Replace the affected circuit pack. Reference: Refer to the appropriate circuit pack replacement procedure in Chapter 6, Supporting procedures. | ||||||
14 |
From the System View, click the Alarm List button and click Refresh. If the install failed condition is still present, contact your next level of support. End of steps |