Prior to performing this procedure:
Refer to Before you begin and Required equipment in this chapter.
Refer to Electrostatic discharge in Chapter 1, Safety.
Complete the following steps to clear a cross-connect loopback condition.
1 |
From the WaveStar® CIT System View, click the Alarm List button and locate the cross-connect loopback condition in the resulting alarm list. |
2 |
Refer to the Probable Cause column in the alarm list, and note the corresponding tributary AID. |
3 |
From the System View menu, select Fault → Analysis → Cross-Connect Loopback. Expand the appropriate groups, select the affected tributary, and click Select. Result: The cross-connect loopback parameters appear. |
4 |
Select Release and click Apply. Result: A warning appears asking you to confirm executing this command. Click Yes and Close. End of steps |