The system has detected an incoming VCN tributary unit (TU) alarm indication signal (AIS) in an STMN line.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
VC12: Major (MJ), Minor (MN), Not Alarmed (NA) VC3: Critical (CR), Minor (MN), Not Alarmed (NA) SA (VC12): Major (MJ) SA (VC3): Critical (CR) NSA: Minor (MN) |
AID Type |
VC12 Ring Channel (Path) VC3 Ring Channel (Path) |
Date |
Month/day/year that condition was detected |
Time |
Hour:minute:second that condition was detected |
Probable Cause |
AIS (AIS Detected) |
Effect on Service |
SA or NSA |
Alarm Entity Type |
VC12 VC3 |
Description |
inc. VC12 TU-AIS inc. VC3 TU-AIS |
Likely Cause |
Incomplete or incorrect cross-connection provisioning in an end-to-end network; unprotected removal or failure of a circuit pack at the far-end; unprotected optical line failure. |
Visible Indication |
Lighted CR/MJ or MN/ABN LED on SYSCTL faceplate. |
Action |
Proceed to Procedure 5-38: Clear "inc. STSN/VCN" conditions/alarms. |