The system has detected a tributary unit (TU) loss-of-pointer (LOP) condition. A valid STMN pointer could not be found for eight consecutive frames in the identified STMN signal.
Alarm Data |
Value/Meaning |
---|---|
Severity Levels |
VC12: Major (MJ), Minor (MN) VC3: Critical (CR), Minor (MN) SA (VC12): Major (MJ) SA (VC3): Critical (CR) NSA: Minor (MN) |
AID Type |
VC12 Ring Channel (Path) VC3 Ring Channel (Path) |
Date |
Month/day/year that condition was detected |
Time |
Hour:minute:second that condition was detected |
Probable Cause |
LOP (Loss of Pointer) |
Effect on Service |
SA or NSA |
Alarm Entity Type |
VC12 VC3 |
Description |
inc. VC12 TU-LOP inc. VC3 TU-LOP |
Likely Cause |
If this condition occurs on only one STMN line, the likely cause is failure of an STMN circuit pack at the near end or far end of the line. If the condition affects the same pointer in both STMN lines of an STMN interface, the cause could be unprotected failure of an VCN cross-connected circuit pack in the adjacent network element or cross-connection mismatch between VCN. An unprotected line/port carrying service failed: SA. A protected line/port failed: NSA. |
Visible Indication |
Lighted CR/MJ or MN/ABN LED on SYSCTL faceplate a flashing FAULT LED on the alarmed circuit pack. |
Action |
Proceed to Procedure 5-38: Clear "inc. STSN/VCN" conditions/alarms. |
Copyright © 2011 Alcatel-Lucent. All rights reserved. |