Procedure 6-5: Display Digital Diagnostics Monitoring information for optical PTMs

- Overview

Use this procedure to display Digital Diagnostics Monitoring (DDM) information for optical PTMs.

- Before you begin

Obtain the work instructions for this procedure.

Step
 
1

Log in to the VLNC4x/VLNC6x circuit pack.


2

From the Navigation menu, select Port → Ethernet Port → Digital Diagnostics Monitoring.

Result:

The Digital Diagnostics Monitoring screen displays.


3

In the Interface drop-down box, select All or an individual port being monitored.

Result:

The Digital Diagnostics Monitoring screen displays the following information:

Parameter

Description

CLI command

Interface

The Slot/Port that supports optical SFPs.

show ddm

Name

Pluggable transmission module name representing the rate(s) supported by the PTM. It is a character string containing one or more rates separated by "//".

See show ddm command in Switching Commands CLI document for details.

Qualifier

Pluggable transmission module qualifier. It is a character string containing one or more qualifiers separated by "//".

See show ddm command in Switching Commands CLI document for details.

Rx Power

PTM optical receive power in dBm. Valid values: -40.0 to +8.2 or "LOS".

Tx Power

PTM optical transmit power in dBM. Valid values: -40.0 to +8.2 or "NA" meaning the laser is turned off.

Laser Bias Current

PTM laser bias current in milliamperes. Valid values: 0.0 to 131.0.

Power Supply Voltage

PTM measured power supply voltage in volts. Valid values: 0 to +6.55.

Temperature

PTM transceiver temperature in degrees Celcius. Valid values: -128.0 to +128.0.

Calibration

Calibration mode Valid values: external or internal