Procedure 5-4.9: Serial (Console) port configuration

- Overview

Use this procedure to configure the RS-232 console serial port for connection of the switch to a terminal desktop system running terminal emulation software.

The RS-232 (RS232 M1) port on the front of the VLIU connects to the Main 1 slot. The RS-232 (RS232 M2) port on the front of the VLIU connects to the Main 2 slot.

Step
 
1

Login to the VLNC4x/VLNC6x.


2

From the Navigation menu, select System → Configuration → Serial Port.

Result:

The Serial Port Configuration window displays the current configuration.


3

Enter/Select the following parameters as required, then click Submit.

Parameters:

  • Serial Port Login Timeout (minutes) — Specifies how many minutes of inactivity should occur on a serial port connection before the switch closes the connection. Enter a number between 0 and 160. The factory default is 5. Entering 0 disables the timeout.

  • Baud Rate (bps) — Select the default baud rate for the serial port connection from the pull-down menu. You may choose from 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200 baud. The factory default is 9600 baud.

Equivalent CLI commands:

  • From the Line Config Mode, enter serial baudrate <rate_value> to provision the communication rate of the terminal interface. The supported rates are 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. Default is 9600.

  • From the Line Config Mode, enter serial timeout <timeout_value> to specify the maximum connect time, in minute, that a serial console login will remain active without console activity. A value of 0 indicates that a console can be connected indefinitely. Range: 0 - 160. Default is 5.


End of steps