Procedure 9-2: Set/view the parameters for the TMPLS global network settings

- Overview

Use this procedure to provision T-MPLS global network settings on the VLNC42B.

Step
 
1

From the Navigation menu, select TMPLS → Global Network.

Result:

The Global Network Configuration screen displays.


2

From the OAM CV Period drop-down box, select the required value.

Valid values:

  • 0 (3.33ms, 10ms, 100msm 1s, 10s, 20ms, 50ms)

  • 2 (3.33ms, 10ms, 100ms, 1s, 10s, 1m)

This parameter selects the value range for CV Period in OAM CV frames. The default value for this parameter is 2.

If there is a Tunnel Segment which has its CV Period defined to be 20ms or 50ms, then changing from 0 to 2 is not allowed. If there is a Tunnel Segment which has its CV Period defined to be 1m, then changing from 2 to 0 is not allowed.

Note that the PHB Range value is fixed in this release to 2 (EF, HIGH2, AF1, AF2, AF3, AF4, DE, LOW2.)


End of steps

Copyright © 2011 Alcatel-Lucent. All rights reserved.