Radio Equipment Health Monitoring Details report

Radio Equipment Health Monitoring Details report overview

The Radio Equipment Health Monitoring Details report shows the detailed port information of the power voltage, current and temperature values of the selected port. The default unit for temperature is Celsius. The report can be generated based on the port selected in the details report.

Use cases

Capacity planning—Use the report to examine the power voltage, current and temperature values on NEs of the respective ports.

Prerequisites

To create a Radio Equipment Health Monitoring Details report, perform the following items in the NFM-P:

Report characteristics

The following table lists the principal report characteristics.

Note: The value of -99 means the data value is not available.

Table 15-24: Radio Equipment Health Monitoring Details report characteristics

Characteristic

Value

Statistics type

Performance statistics

NSP flow collector required

No

NE types supported

Wavence MSS-1, Wavence MSS-4, Wavence MSS-8, Wavence MSS-O, Wavence MSS-E, Wavence MSS-HE, Wavence MSS-XE, Wavence MSS-1c, Wavence SA, 9500 MPR-A Chassis 1, 9500 MPR-A Chassis 4, 9500 MPR-A Chassis 8, 9500 MPR-E Chassis 1, 9500 MPR-E Chassis 4, 9500 MPR-E Chassis 8, 9500 MSS-1c, 9500 MSS-O ANSI, 9500 MSS-O ETSI, 9500 SA

Report inputs

Prompt

Notes

Start date

End date

Calendar date or relative date (for example, two days ago) and time

Granularity

Aggregation types:

  • None (raw data)

  • Hourly

  • Daily

  • Monthly

Port

Select a port from the drop-down list

Temperature Unit

Celsius or Fahrenheit

Temperature Threshold

Specify the value using expression like >,<,=,<=,>=.

Power Threshold

Current Threshold

Voltage Threshold

Logo Resource ID

The logo to add to the report. Enter the Resource ID of the logo image in the Images folder. The default is the Nokia logo. To create the report without a logo, leave the Logo Resource ID field blank.

Logo Position

Choose Left, Middle, or Right. The logo appears on the left on the first page of the report if you choose Left or Middle.

Show report output on one page

Select the check box to enable pagination.

Note: Using the Show report output on one page option when creating reports as drill-downs may impact report rendering time. Nokia recommends disabling the Show report output on one page option when creating reports.

Apply

Applies all the parameters and prepares the report based on the parameters entered.

Reset

Resets all the parameters to default value.

Drill-down support

No

Example

The following figure shows a report example.

Figure 15-30: Radio Equipment Health Monitoring Details report
Radio Equipment Health Monitoring Details report