To retrieve I&C files stored by Wavence devices
Prerequisites
I&C file retrieval is supported on MSS-4/8 nodes, Wavence Release 23A or later.
Before you can retrieve I&C files from a Wavence device, a File Retrieval Policy must be configured for the device. See To assign a file retrieval policy to a Wavence device for information about assigning a policy, and To create or modify a file retrieval policy for information about configuring a policy.
Steps
1 |
Choose Administration→NE Maintenance→File Retrieval from the NFM-P main menu. The File Retrieval form opens. |
2 |
Select the I&C file retrieval policy configured for the device and click Properties. |
3 |
Confirm the parameters in the SFTP Settings panel. For I&C file retrieval from CoreEvo nodes the host fingerprint must be ECDSA. |
4 |
Click on the File Retrieval Status tab. The supported Wavence devices that are managed by NFM-P are listed. |
5 |
Choose a device and click Retrieve Logs. The Log Retrieval State column displays the status of log retrieval. The log files are copied from the SFTP server to the NFM-P server. Retrieved logs are displayed in the Logs tab. Note: I&C files are stored on the NFM-P in /opt/nsp/nfmp/nelogs/Wavence/. Folders are created for each nodeID from which files were retrieved, containing a I and C Parameters folder with the retrieved files. End of steps |