How do I create baselines?

CAUTION 

CAUTION

Service Disruption

The name of an object, including subscriptions, baselines, indicators, templates, and chart profiles, cannot contain a semicolon (;) or backslash (\).

The use of these characters in an object identifier will result in corrupted data that must be deleted by Nokia support.

Important! If you are creating multiple baselines, the create operation may take a long time and cannot be stopped. Ensure that you are able to wait for the operation to complete before proceeding. For example, average maximum time required for creation of 100 baselines is 30 s; average maximum time required for creation of 10 000 baselines is 30 min.

Steps
 

Open Data Collection and Analysis Management, Baselines.


Click png2.pngBASELINES.


In the Create Baselines form that opens, configure the General parameters as needed.


Enter information in the Telemetry Type field. As you type, the field filters for available telemetry types to match your input.

Choose the telemetry type you need from the list of matches.


Click png2.pngCOUNTERS .


In the Add Counters form that opens, choose the required counters and click ADD.


Configure the Counter parameters as needed.


Click png2.pngCOUNTERS to add additional counters.


In the Object Filter field, enter filtering information as needed to filter the collected data.

As you type, the field provides suggestions for available filters to match your input and identifies incorrect syntax.


10 

Click VERIFY RESOURCES.

NSP searches for resources that are collecting statistics to match the telemetry type and object filter.

Note: NFM-P resources appear in the list after the NFM-P collects the statistics. Therefore, you need to wait for the current collection interval to end before the NFM-P resource appears in the list.

If needed, you can click STOP VERIFICATION at any time and Edit Filters & Counters to update the configuration and restart the verification process.


11 

When the resources you need appear in the resources list, click STOP VERIFICATION.


12 

Select the resources you need in the resources list.


13 

In the Detectors panel, add a rule for each counter as needed:

  1. Click png2.pngRULE.

  2. Configure the rule parameters.

Repeat steps 1 and 2 to add detector rules for other counters.


14 

Click CREATE.

End of steps