To perform an 1830 VWM on-demand software upgrade
Before you begin
Configure a software upgrade policy or use the default “VWM OSU Default Policy”.
See To configure a software upgrade policy for more information about configuring a software upgrade policy.
Steps
1 |
Choose Administration→NE Maintenance→Software Upgrade from the NFM-P main menu. The Software Upgrade form opens. |
2 |
Click on the Software Images tab and then on the 1830 VWM OSU Software Images tab. |
3 |
Note: NFM-P requires only CATALOG and osu.isd files to be present in the specified folder to import the image. Copy the CATALOG and osu.isd files to a separate folder or remove all other files from the folder before you begin with import operation. Perform one of the following:
|
4 |
Choose an appropriate 1830 VWM software image and click Audit. The Confirm Audit Settings dialog box opens. |
5 |
Configure the Audit Settings parameter, choose an 1830 VWM device and click OK. |
6 |
Click Load and choose the 1830 VWM device. |
7 |
Click Activate and choose the 1830 VWM device. |
8 |
Click Revert and choose an 1830 VWM device to revert to a previously committed software release, if required. |
9 |
Click Commit and choose the 1830 VWM device. |
10 |
Save your changes and close the forms. End of steps |