To perform CPRI monitoring using 1830 VWM TLU 9M MON ports

Before you begin

Ensure that the States parameter of the target ports (client and its corresponding line port, for example, if the target port is C1, its corresponding line port is L1) are configured as Maintenance, if you need the monitoring mode to be configured as tap Insert or terminate.

Steps
 

On the equipment tree, expand Network→1830 VWM OSU→Shelf (TLU 9M)→Card (TLU 9M).


Right-click on the MON port and choose Properties. The Physical Port (Edit) form opens.


Click on the Interface Monitor tab.


Configure the Monitor Mode parameter.


Click Select in the Interface Monitor Details panel and the Select Target Port form opens.


Select the target port and click OK. The port details are updated in the Interface Monitor Details panel.

Note:

If...

then...

you configure the Monitoring Mode parameter as Listen in Step 4,

the target ports can be in up, down, or maintenance state.

you configure the Monitoring Mode parameter as Tap Inset or Terminate in Step 4,

only the target ports that have the States Parameter configured as Maintenance are listed for selection in the Select Target Port form.


Click Apply.


Click on the States tab and configure the Administrative State parameter as Up.


Save your changes and close the form.

End of steps