To configure an MDA
Steps
1 |
On the equipment tree, right-click on a device and choose Properties. The Network Element form opens. |
2 |
On the Network Element tree, expand the Shelf object→Card Slot object. |
3 |
Perform one of the following:
|
4 |
Configure the required parameters. The Clock Mode parameter value must be set to Differential in order to configure the Differential Timestamp Frequency (kHz) parameter. The Assigned Daughter Card Type and In MDA Carrier Module Slot parameters are configurable only during daughter-card creation. Note: The ATM Mode parameter must be set to a value of max16k-vc for PPPoA and PPPoEoA to be supported. |
5 |
Click on the Daughter Card tab and configure the required parameters. Note: Before you configure the MDA Mode parameter, you must shut down all of the ports and remove all of the subchannels and bundles from the MDA. |
6 |
To configure named buffer pools: Note: You must enable pool mode on the parent I/O card to enable named buffer pool support. See To enable named pool mode for more information.
|
7 |
If required, select a policy in the Network Queue Policy panel. For 7450 ESS, 7750 SR, and 7950 XRS NEs, network queue policies are assigned to forwarding planes; see To assign a network queue policy to a forwarding plane. |
8 |
If required, select a Network Ingress Fabric Profile and an Access Ingress Fabric Profile in the Fabric Profiles panel. |
9 |
If required, select a Network Ingress Security Queue and an Access Ingress Security Queue in the Security Queue Policies panel. |
10 |
If required, select a policy in the Egress HSMDA Pool Policy panel. Note: You must enable pool mode on the parent I/O card to enable HSMDA pool support. See To enable named pool mode for more information. |
11 |
Configure the required parameters in the HSMDA Aggregate Queue Burst panel. |
12 |
To assign a network queue policy and network policy of ring type to a 7705 SAR:
|
13 |
Select an Access Ingress Shaper policy in the Shaper Policies panel. Note: The Shaper policy is supported on all Ethernet MDAs on the 7705 SAR-8 and 7705 SAR-18 except the following: The Shaper policy is supported on all integrated MDAs on all 7705 SAR variants except the following: |
14 |
To configure MAC management:
|
15 |
To configure the cellular MDA on 7705 SAR-Hm, click on the Cellular tab and configure the required parameters. When the 7705 SAR-Hm is operating in dual SIM mode, you can configure the SIM switchover behavior to be automatic based on specified failover criteria. When you set the Active SIM Card parameter to Automatic, you can configure the Down Recovery Interval (Min) and Down Recovery Criteria parameters for each SIM card. These parameters specify failover criteria to determine when to automatically switch to the backup SIM. If you set the Down Recovery Interval (Min) parameter to be less than the Fail Duration (Min) value set on the cellular port, a node reboot happens instead of a SIM switchover. |
16 |
If required, click on the Wlan Radio tab and configure the parameters. |
17 |
If required, click on the Network Interfaces tab to add a network interface card. |
18 |
Click Add. The Create Network Interface - Routing Instance form opens. See To create an L3 network interface on a routing instance for information on creating a network interface. |
19 |
If required, perform To configure IMPM on an MDA to configure IMPM on the daughter card. |
20 |
For 7450 ESS, 7750 SR, and 7950 XRS NEs, network ingress pools are configured on forwarding planes; see To configure a network ingress pool on a forwarding plane. |
21 |
To configure ATM:
|
22 |
Save your changes and close the forms. End of steps |