To perform an on-demand OmniSwitch backup or configuration save
Steps
Note: The following limitations apply to an OmniSwitch virtual chassis node, depending on how the node is managed:
-
If the NE is managed using the out-of-band management IP address, and is a single-shelf node, vcboot.cfg and vcsetup.cfg files are backed up from primary.
-
If the NE is managed using out-of-band management IP address and is a multi-shelf node, the following are backed up:
If any of the NE is unreachable from the NFM-P server, the backup operation fails.
-
If the NE is managed using a VLAN-based management IP address or an in-band management IP address, the vcboot.cfg file is backed up from primary.
|
|
1 |
On the Equipment tree, expand an OmniSwitch object, right-click on a shelf object, and choose Properties. The Shelf (Edit) form opens.
|
2 |
Click on the Software Control Module tab and set the Command to Apply parameter to Certified.
|
3 |
Click Resync.
Note: You must resynchronize the NE to ensure the /flash/working and /flash/certified directory contents are the same, even though the Certified Status displays Certified.
|
4 |
Save your changes and close the form.
|
5 |
Choose Administration→NE Maintenance→Backup/Restore from the NFM-P main menu. The Backup/Restore form opens.
|
6 |
Click on the Backup/Restore Policy tab. The backup policies are listed.
|
7 |
Select a policy and Click Properties. The Backup Policy (Edit) form opens.
|
8 |
Click on the Backup/Restore Status tab. The tab lists NEs of the type specified by the Policy Type parameter setting on the General tab.
|
9 |
Select an NE and click Backup or Save Config, depending on the operation that you need to perform.
|
10 |
The operation begins; the Last Operation Details column displays the operation status.
|
11 |
When the operation is complete, close the forms.
End of steps |